ELECTRICAL AND ELECTRONICS ENGINEERING - lab facility
DC Machines Lab :
- Area - 246.53 Sq.m.
- 15 batches (each batch of 3 students) of students can utilize the lab effectively at a time.
- The lab will be utilized by EEE, ECE, CSE, B.Tech(AFT) and Mechanical Students.
- The machineries in the lab includes,
- DC shunt, Series and Compound Motors with belt load arrangements
- Motor – Generator sets
- Resistive Loads
- Rectifiers (36V, 230V)
AC Machines Lab :
- Area - 366.96 Sq.m
- 20 batches (each batch of 3 students) of students can utilize the lab effectively at a time.
- The lab will be utilized by EEE, ECE, CSE, B.Tech(AFT) and Mechanical Students.
- The machineries in the lab includes
- Synchronous Motors
- Alternators (salient & non salient) Induction
- Motors (1phase & 3 phase),
- Transformers (1phase, 3 phase),
- Auto transformers (1phase& 3 phase)
- Linear Induction Motor
- Winding Study Motors
- Sectional models of starters.
- Relay testing kit.
Measurement & Instrumentation Lab :
- Area - 119.04 Sq.m.
- The equipments include
- Linear Displacement Transducer
- AC & DC bridge kits
- Instrumentation Amplifier kit
- A/D & D/A Converter kit
- 1ф-Energy meter
- Current Transformer,Potential Transformer
- Transducer
Microprocessor Lab & Digital IC Lab :
- Area - 133.88 Sq.m.
- 45 Students can utilize the lab at a time.
- The equipments include
- 8085, 8086, Micro Controller Kits
- Temperature controller kit
- A/D interfacing kits
- Stepper Motor Interfacing
- Traffic Light controller
- DAC Card
- Interfacing Cards are available in this lab
- CRO, Keyboard and digital controller
Power Electronics & Drives Lab :
- Area - 186.825 Sq.m
- Maximum of 45 students can utilize the lab at a time
- The major equipments include
- Convertor Kits
- Triggering Modules (R, R C & UJT)
- Chopper Kits, Cycloconverter Kits
- 1 phase and 3 phase Induction Motor Drive Control using IGBT Chopper
- Microprocessor based Firing Control for DC Shunt Motor etc.
- DSP Controller
- 3 phase converter and Inverter
Simulation Lab :
- Area -141.75 Sq.m
- Around 50 students can utilize the lab simultaneously
- One server and 41 nodes
- 3kVA and 10kVA UPS
- The major software include
- ETAP 4.7.0, PSCAD 3.0.8
- ORCAD version 9.0
- AU Power Lab 1.0
- Matlab 7.2
Library
- Area - 20.9Sqm
- A seating capacity of 10 members
- Total No.of Books :-
Volumes - 709
Titles - 665
Journals - 14.
Power House
- A H.T. supply with a maximum demand of 400KVA is availed from E.B.
- A 500KVA 22KV/433V, Three phase transformer with OLTC has been installed for the entire distribution of supply throughout the college.
- Two diesel generator-sets with capacity of 125KVA & 380KVA are available for continuous emergency supply
Class Room
Bright and airy classrooms equipped with modern teaching aids such as OHPS, VHPs etc.